
Chapter 5:
68 Simon XT TableTop Control Panel Installation Manual
X10 siren and lamp module functions
All sirens turn off when the system is disarmed or when the siren timeout expires.
Siren priority is fire (highest priority), intrusion, and emergency. Table 33 below
identifies the light information for each of these siren types.
Table 33: Alarm siren and X10 light information
If an alarm of greater priority occurs during an alarm of lower priority, the greater
priority alarm sirens sound. Fire alarms sound a temporal 3 pattern (0.5 seconds
on, 0.5 seconds off for three beeps then 1.5 seconds off).
Note: The X10 siren must be set to unit #9 to “hear” emergency alarms and
status beeps. To hear emergency alarms only, set to unit #10.
Komentarze do niniejszej Instrukcji