Interlogix NS3702-24P-4S User Manual Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Akcesoria komunikacja Interlogix NS3702-24P-4S User Manual. Interlogix NS3702-24P-4S User Manual User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - User Manual

NS3702-24P-4S User Manual P/N 1072832 • REV 00.01 • ISS 14JUL14

Strona 2

10 1. INTRODUCTION NS3702-24P-4S - 24-Port 10/100/1000Mbps 802.3at PoE+ ports, 4-Port Shared Gi

Strona 3 - TABLE OF CONTENTS

100 The Page includes the following fields: Object Description  Source MAC Address The Sourc

Strona 4

101 The Page includes the following fields: .Object Description  Group ID Indicates the grou

Strona 5

102 Figure 4-5-4 : LACP Port Configuration Page Screenshot

Strona 6

103 The Page includes the following fields: Object Description  Port The switch port number.

Strona 7

104 4.5.3 LACP System Status This Page provides a status overview for all LACP instances. The

Strona 8

105 4.5.4 LACP Port Status This Page provides a status overview for LACP status for all ports.

Strona 9

106 Auto-refresh : Automatic refresh occurs every 3 seconds. 4.5.5 LACP Port Statistics This

Strona 10 - 1. INTRODUCTION

107 4.6 VLAN 4.6.1 VLAN Overview A Virtual Local Area Network (VLAN) is a network topology conf

Strona 11 - 1.2 Product Description

108 4.6.2 IEEE 802.1Q VLAN In large networks, routers are used to isolate broadcast traffic

Strona 12

109 allows Spanning Tree to be enabled on all ports and work normally. Some relevant terms: -

Strona 13

11 1.2 Product Description Ideal Solution for Secure IP Surveillance Construction Particularly

Strona 14 - 1.3 How to Use This Manual

110 Port VLAN ID Packets that are tagged (are carrying the 802.1Q VID information) can

Strona 15 - 1.4 Product Features

111 nor the host at the other end of the connection supports VLANs, then you should add this po

Strona 16

112  Tagged: Ports with tagging enabled will put the VID number, priority and other VLAN info

Strona 17

113 The Managed Switch supports multiple VLAN tags and can therefore be used in MAN applicatio

Strona 18 - 1.5 Product Specifications

114 Object Description  Allowed Access VLANs This field shows the allowed Access VLANs, it o

Strona 19

115 Port VLAN Configuration The VLAN Port Configuration screen in Figure 4-6-2 appears. Figure

Strona 20

116  The VLANs that a trunk port is member of may be limited by the use of Allowed VLANs  Fr

Strona 21

117 tagged on egress, they will be tagged with a C-tag. S-Port: On ingress, frames with a VL

Strona 22 - 2. INSTALLATION

118 Untag All All frames, whether classified to the Port VLAN or not, are transmitted withou

Strona 23 - 2.1.2 LED Indications

119 Figure 4-6-4: VLAN Membership Status for Static User Page Screenshot

Strona 24

12 Intelligent Powered Device Alive-Checking The NS3702 can be configured to monitor connecte

Strona 25 - 2.1.3 Switch Rear Panel

120 The Page includes the following fields: Object Description  VLAN User A VLAN User is a m

Strona 26 - 2.2 Installing the Switch

121 uttons : Select VLAN Users from this drop down list. Auto-refresh : Check this box to refre

Strona 27 - 2.2.2 Rack Mounting

122 4.6.5 VLAN Port Status This Page provides VLAN Port Staus. The VLAN Port Status screen in F

Strona 28

123  Untagged VLAN ID Shows UVID (untagged VLAN ID). Port's UVID determines the packet&a

Strona 29

124 Figure 4-6-6 Private VLAN Membership Configuration page screenshot

Strona 30 -  Connect the Fiber Cable

125 The page includes the following fields: Object Description  Delete To delete a private V

Strona 31

126 database servers on the inside segment, but are not allowed to communicate with each other

Strona 32 - 3. SWITCH MANAGEMENT

127 This Page is used for enabling or disabling port isolation on ports in a Private VLAN. A po

Strona 33

128 4.6.8 VLAN setting example:  Separate VLAN  802.1Q VLAN Trunk  Port Isolate 4.6.8.1

Strona 34 - 3.3 Administration Console

129  Untagged packet entering VLAN 2 1. While [PC-1] transmit an untagged packet enters Port

Strona 35 - 3.4 Web Management

13 Cost-Effective PoE Switch solution for IPv6 Networking Faced with the increasingly large

Strona 36

130 VLAN 3 : Port-4, Port-5 and Port-6 VLAN 1 : All other ports – Port-7~Port-28 Figure 4-6-10

Strona 37 - 4. WEB CONFIGURATION

131 other switches within the same VLAN group. The screen in Figure 4-6-12 appears. Figure 4

Strona 38

132 VLAN 3 : Port-4, Port-5 and Port-6 VLAN 1 : All other ports – Port-7~Port-48 Figure 4-6-14

Strona 39

133 Figure 4-6-15: VLAN Overlap Port Setting & VLAN 1 – The Public Area Member Assign Tha

Strona 40 - 4.1 Main Web Page

134 Setup steps 1. Assign Port Mode Set Port-1~Port-4 in Isolate port. Set Port5 and Port-6 i

Strona 41

135 VLAN 3: Port-3~Port-6. The screen in Figure 4-6-18 appears. Figure 4-6-17: Private VLAN Po

Strona 42 - 4.2 System

136 4.6.9 MAC-based VLAN The MAC-based VLAN enties can be configured here. This Page allows for

Strona 43 - 4.2.1 System Information

137 : Click to add a new MAC-based VLAN entry. : Click to apply changes : Click to undo any c

Strona 44 - 4.2.2 IP Configuration

138 4.6.11 Protocol-based VLAN This Page allows you to add new protocols to Group Name (unique

Strona 45

139 3. For SNAP: Valid value in this case also is comprised of two different sub-values. a.

Strona 46 - 4.2.3 IP Status

14 1.3 How to Use This Manual This User’s Manual is structured as follows: Section 2, INSTALLAT

Strona 47 - 4.2.4 Users Configuration

140 Figure 4-6-21: Group Name to VLAN Mapping Table Page Screenshot

Strona 48 - Add / Edit User

141 The Page includes the following fields: Object Description  Delete To delete a Group Nam

Strona 49

142 4.7 Spanning Tree Protocol 4.7.1 Theory The Spanning Tree protocol can be used to detect an

Strona 50

143 STP communicates between switches on the network using Bridge Protocol Data Units (BPDUs).

Strona 51 - 4.2.5 Privilege Levels

144  Disabled – the port only responds to network management messages and must return to the

Strona 52

145 STP Operation Levels The Switch allows for two levels of operation: the switch level and th

Strona 53 - 4.2.6 NTP Configuration

146 The following are the user-configurable STP parameters for the switch level: Parameter Des

Strona 54 - 4.2.7 Time Configuration

147 Port priority 128 Port cost 0 Bridge Priority 32,768 User-Changeable STA Parameters The

Strona 55 - 4.2.8 UPnP

148 STP calculation of the most current Bridge and Port settings. Now, if switch A broadcasts

Strona 56

149 Figure 4-7-3: After Applying the STA Rules The switch with the lowest Bridge ID (switch C)

Strona 57 - 4.2.9 DHCP Relay

15 1.4 Product Features  Physical Port  24-Port 10/100/1000Base-T RJ-45 copper with IEEE 80

Strona 58

150 ‧ Extension – Multiple Spanning Tree Protocol (MSTP) : Defines an extension to RSTP to fur

Strona 59 - 4.2.10 DHCP Relay Statistics

151 Forwarding (used in STP compatible mode). Valid values are in the range 4 to 30 seconds -De

Strona 60

152 : Click to apply changes : Click to undo any changes made locally and revert to previousl

Strona 61 - 4.2.11 CPU Load

153 4.7.4 CIST Port Configuration This Page allows the user to inspect the current STP CIST po

Strona 62 - 4.2.12 System Log

154 Valid values are in the range 1 to 200000000.  Priority Controls the port priority. This

Strona 63 - 4.2.13 Detailed Log

155 : Click to undo any changes made locally and revert to previously saved values. By default

Strona 64 - 4.2.14 Remote Syslog

156 4.7.5 MSTI Priorities This Page allows the user to inspect the current STP MSTI bridge inst

Strona 65

157 4.7.6 MSTI Configuration This Page allows the user to inspect the current STP MSTI bridge i

Strona 66 - 4.2.15 SMTP Configuration

158 MSTI Mapping Object Description  MSTI The bridge instance. The CIST is not available fo

Strona 67 - 4.2.16 Web Firmware Upgrade

159 Figure 4-7-10 : MST1 MSTI Port Configuration Page Screenshot The Page includes the foll

Strona 68 - 4.2.17 TFTP Firmware Upgrade

16  STP, IEEE 802.1D Spanning Tree Protocol  RSTP, IEEE 802.1w Rapid Spanning Tree Protocol

Strona 69 - 4.2.18 Save Startup Config

160 values are in the range 1 to 200000000.  Priority Controls the port priority. This can be

Strona 70 - 4.2.20 Configuration Upload

161 AlternatePort BackupPort RootPort DesignatedPort Disable  CIST State The c

Strona 71 - 4.2.22 Configuration Delete

162  STP The number of legacy STP Configuration BPDU's received/transmitted on the port.

Strona 72 - 4.2.23 Image Select

163 4.8 Multicast 4.8.1 IGMP Snooping The Internet Group Management Protocol (IGMP) lets host a

Strona 73 - 4.2.25 System Reboot

164 Figure 4-8-2: Multicast Flooding

Strona 74 - 4.3.1 SNMP Overview-[

165 Figure 4-8-3: IGMP Snooping Multicast Stream Control IGMP Versions 1 and 2 Multicast group

Strona 75

166 0x11 Specific Group Membership Query (if Group Address is Present) 0x16 Membership Report

Strona 76

167 Figure 4-8-4: IGMP State Transitions  IGMP Querier – A router, or multicast-enabled s

Strona 77

168 4.8.2 Profile Table This page provides IPMC Profile related configurations. The IPMC profil

Strona 78

169 profile by using the following buttons: : List the rules associated with the designated p

Strona 79

17  IEEE 802.1X Authentication with Guest VLAN  Built-in RADIUS client to cooperate with th

Strona 80

170  End Address The ending IPv4/IPv6 Multicast Group Address that will be used as an address

Strona 81 - 4.3.5 SNMPv3 Configuration

171 Figure 4-8-7: IGMP Snooping Configuration Page Screenshot The Page includes the following

Strona 82 - 4.3.5.2 SNMPv3 Users

172 unnecessary leave messages to the router side.  Proxy Enable Enable IGMP Proxy. This feat

Strona 83

173 4.8.5 IGMP Snooping VLAN Configuration Each Page shows up to 99 entries from the VLAN table

Strona 84

174 IGMPv2, Forced IGMPv3. Default compatibility value is IGMP-Auto.  PRI (PRI) Priority of I

Strona 85

175 Click "Save". The specific IGMP VLAN starts working after the corresponding stati

Strona 86

176 Object Description  Port The logical port for the settings.  Filtering Profile Select

Strona 87

177 The Page includes the following fields: Object Description  VLAN ID The VLAN ID of the e

Strona 88 - 4.4 Port Management

178 Figure 4-8-9: IGMP Snooping Groups Information Page Screenshot The Page includes the foll

Strona 89

179 The IGMPv3 Information screen in Figure 4-8-12 appears. Figure 4-8-12: IGMP SSM Informatio

Strona 90

18 1.5 Product Specifications Product NS3702-24P-4S Hardware Specifications SFP/mini-GBIC Slo

Strona 91 - 4.4.3 Port Statistics Detail

180 4.8.10 MLD Snooping Configuration This Page provides MLD Snooping related configuration. Th

Strona 92

181  MLD SSM Range SSM (Source-Specific Multicast) Range allows the SSM-aware hosts and route

Strona 93

182 The Page includes the following fields: Object Description  Delete Check to delete the e

Strona 94 - 4.4.5 Port Mirror

183 Buttons : Refreshes the displayed table starting from the "VLAN" input fields. :

Strona 95

184 Figure 4-8-15: MLD Snooping Port Group Filtering Configuration Page Screenshot

Strona 96

185 The Page includes the following fields: Object Description  Port The logical port for th

Strona 97 - 4.5 Link Aggregation

186 The Page includes the following fields: Object Description  VLAN ID The VLAN ID of the e

Strona 98

187 The "Start from VLAN", and "group" input fields allow the user to selec

Strona 99 - 4.5.1 Static Aggregation

188 Figure 4-8-18: MLD SSM Information Page Screenshot The Page includes the following fields

Strona 100

189 4.8.16 MVR (Multicaset VLAN Registration) The MVR feature enables multicast traffic forw

Strona 101 - 4.5.2 LACP Configuration

19 PD @ 15.4 watts 24 units PD @ 30.8 watts 14 units Layer 2 Functions Port Configuration Por

Strona 102

190 Figure 4-8-19: MVR Configuration Page Screenshot The Page includes the following fields:

Strona 103

191 Be Caution: MVR source ports are not recommended to be overlapped with management VLAN port

Strona 104 - 4.5.3 LACP System Status

192 source ports. Subscribers cannot be directly connected to source ports.  Receiver: Config

Strona 105 - 4.5.4 LACP Port Status

193  IGMPv1 Joins Received The number of Received IGMPv1 Joins.  IGMPv2/MLDv1 Reports Recei

Strona 106 - 4.5.5 LACP Port Statistics

194 Object Description  VLAN VLAN ID of the group.  Groups Group ID of the group displayed

Strona 107 - 4.6 VLAN

195 The Page includes the following fields: Object Description  VLAN ID VLAN ID of the group

Strona 108 - 4.6.2 IEEE 802.1Q VLAN

196 4.9 Quality of Service 4.9.1 Understanding QoS Quality of Service (QoS) is an advanced t

Strona 109 - ■ 802.1Q VLAN Tags

197 3. Create a QoS profile which associates a service level and a classifier. 4. Apply a QoS

Strona 110

198 4.9.3 Port Classification This Page allows you to configure the basic QoS Ingress Classific

Strona 111

199 CoS is shown in parentheses after the configured default CoS.  DPL Controls the default d

Strona 112

2 Copyright © 2014 United Technologies Corporation Interlogix is part of UTC Building & In

Strona 113

20 Routing Protocols IPv4 software Static Routing IPv6 software Static Routing Management Funct

Strona 114

200 4.9.4 Port Scheduler This Page provides an overview of QoS Egress Port Schedulers for all s

Strona 115

201 4.9.5 Port Shaping This Page provides an overview of QoS Egress Port Shapers for all switch

Strona 116

202 4.9.5.1 QoS Egress Port Schedule and Shapers The Port Scheduler and Shapers for a specific

Strona 117

203  Queue Shaper Excess Controls whether the queue is allowed to use excess bandwidth.  Qu

Strona 118 - 4.6.4 VLAN Membership Status

204 Figure 4-9-6: QoS Egress Port Tag Remarking Page Screenshot

Strona 119

205 The Page includes the following fields: Object Description  Port The logical port for th

Strona 120

206 : Click to apply changes : Click to undo any changes made locally and revert to previousl

Strona 121

207  Classify Classification for a port have 4 different values.  Disable: No Ingress DSC

Strona 122 - 4.6.5 VLAN Port Status

208 4.9.8 DSCP-based QoS This Page allows you to configure the basic QoS DSCP-based QoS Ingress

Strona 123 - 4.6.6 Private VLAN

209  QoS Class QoS Class value can be any of (0-7)  DPL Drop Precedence Level (0-1)

Strona 124

21 RFC 3376 IGMP version 3 RFC 2710 MLD version 1 RFC 3810 MLD version 2 Environment Operating

Strona 125 - 4.6.7 Port Isolation

210 4.9.9 DSCP Translation This Page allows you to configure the basic QoS DSCP Translation set

Strona 126

211 for QoS class and DPL map. There are two configuration parameters for DSCP Translation –

Strona 127

212 Object Description  QoS Class Available QoS Class value ranges from 0 to 7. QoS Class (0

Strona 128 - 4.6.8 VLAN setting example:

213 Broadcast: Only Broadcast MAC addresses are allowedd. The default value is 'Any&a

Strona 129

214 4.9.11.1 QoS Control Entry Configuration The QCE Configuration screen in Figure 4-9-13 ap

Strona 130

215 or range(0-1, 2-3, 4-5, 6-7, 0-3, 4-7) or 'Any' DEI Drop Eligible Indicator:

Strona 131

216 Source IP IPv6 source address: (a.b.c.d) or 'Any', 32 LS bits DSCP Diffserv Cod

Strona 132

217 The Page includes the following fields: Object Description  User Indicates the QCL user.

Strona 133 - 4.6.8.3 Port Isolate

218 'yes'. : Click to refresh the Page. 4.9.13 Storm Control Configuration Storm

Strona 134

219  Enable Controls whether the storm control is enabled on this switch port.  Rate Contro

Strona 135

22 2. INSTALLATION This section describes the hardware features and installation of the Managed

Strona 136 - 4.6.9 MAC-based VLAN

220 4.9.14 WRED This page allows you to configure the Random Early Detection (RED) settings f

Strona 137 - 4.6.10 MAC-based VLAN Status

221 This value is restricted to 0-100. RED Drop Probability Function The following illustratio

Strona 138 - 4.6.11 Protocol-based VLAN

222 4.9.15 QoS Statistics This Page provides statistics for the different queues for all swit

Strona 139

223 4.9.16 Voice VLAN Configuration The Voice VLAN feature enables voice traffic forwarding o

Strona 140

224 The Page includes the following fields: Object Description  Mode Indicates the Voice

Strona 141

225  Port Discovery Protocol Indicates the Voice VLAN port discovery protocol. It will only w

Strona 142 - 4.7 Spanning Tree Protocol

226 4.9.17 Voice VLAN OUI Table Configure VOICE VLAN OUI table on this Page. The maximum entry

Strona 143

227 Buttons : Click to add a new access management entry. : Click to apply changes : Click to

Strona 144

228 4.10 Access Control Lists ACL is an acronym for Access Control List. It is the list table o

Strona 145

229 EType: The ACE will match Ethernet Type frames. Note that an Ethernet Type based ACE wil

Strona 146

23 Console Port The console port is a RJ-45 port connector. It is an interface for connecti

Strona 147

230 4.10.2 Access Control List Configuration This Page shows the Access Control List (ACL), whi

Strona 148

231 Permit: Frames matching the ACE may be forwarded and learned. Deny: Frames matching t

Strona 149

232 4.10.3 ACE Configuration Configure an ACE (Access Control Entry) on this Page. An ACE consi

Strona 150

233 The allowed range is 0x0 to 0xff.  Frame Type Select the frame type for this ACE. These f

Strona 151 - Advanced Settings

234  MAC Parameters Object Description  SMAC Filter (Only displayed when the frame type is

Strona 152 - 4.7.3 Bridge Status

235 specified (tag priority is "don't-care".)  ARP Parameters The ARP parame

Strona 153

236  Target IP Mask When "Network" is selected for the target IP filter, you can en

Strona 154

237 choose this value. A field for entering an IP protocol filter appears. ICMP: Select IC

Strona 155

238 Network: Source IP filter is set to Network. Specify the source IP address and source IP

Strona 156 - 4.7.5 MSTI Priorities

239 specific value. The allowed range is 0 to 255. A frame that hits this ACE matches this IPv6

Strona 157 - 4.7.6 MSTI Configuration

24 NS3702-24P-4S LED Indication Table  LED definition  System LED Color Function P

Strona 158

240 "don't-care"). Specific: If you want to filter a specific ICMP code filt

Strona 159 - MSTx MSTI Port Configuration

241  TCP/UDP Destination Number When "Specific" is selected for the TCP/UDP destina

Strona 160 - 4.7.8 Port Status

242  Ethernet Type Parameters The Ethernet Type parameters can be configured when Frame Type

Strona 161 - 4.7.9 Port Statistics

243 4.10.4 ACL Ports Configuration Configure the ACL parameters (ACE) of each switch port. Thes

Strona 162

244 value is "Disabled".  Logging Specify the logging operation of this port. The a

Strona 163 - 4.8 Multicast

245 4.10.5 ACL Rate Limiter Configuration Configure the rate limiter for the ACL of the switch.

Strona 164

246 4.11 Authentication This section is to control the access of the Managed Switch, includes t

Strona 165 - Type Response Time

247 3rd party switch or a hub) and still require individual authentication, and that the client

Strona 166

248 Figure 4-11-1  Client—the device (workstation) that requests access to the LAN and switc

Strona 167

249 header is removed, leaving the EAP frame, which is then encapsulated for Ethernet and sent

Strona 168 - 4.8.2 Profile Table

25 2.1.3 Switch Rear Panel The rear panel of the Managed Switch indicates an AC inlet power soc

Strona 169 - 4.8.3 Address Entry

250  Ports in Authorized and Unauthorized States The switch port state determines whether

Strona 170

251 Figure 4-11-3: Authentication Method Configuration Page Screenshot

Strona 171

252 The Page includes the following fields: Object Description  Client The management client

Strona 172

253 Figure 4-11-4: Network Access Server Configuration Page Screenshot The Page includes the f

Strona 173

254 Enabled after the interval specified by the Reauthentication Period. Reauthentication for 8

Strona 174

255 Single 802.1X Multi 802.1X MAC-Based Auth. If a client is denied access - either b

Strona 175

256 The "Guest VLAN Enabled" checkbox provides a quick way to globally enable/disable

Strona 176 - 4.8.7 IGMP Snooping Status

257 authentication. Force Unauthorized In this mode, the switch will send one EAPOL Failure fr

Strona 177 - 4.8.8 IGMP Group Information

258 EAPOL Start frame retransmission rate. Single 802.1X In port-based 802.1X authentication,

Strona 178 - 4.8.9 IGMPv3 Information

259 supplicants that might be on the port. The maximum number of supplicants that can be attach

Strona 179

26 2.2 Installing the Switch This section describes how to install your Managed Switch and make

Strona 180

260 supplicant is successfully authenticated. If present and valid, traffic received on the sup

Strona 181

261 For trouble-shooting VLAN assignments, use the "Monitor→VLANs→VLAN Membership and VLAN

Strona 182

262 transmission of EAPOL Request Identity frames is configured with EAPOL Timeout. If Allow Gu

Strona 183

263 port and will not cause the clients to get temporarily unauthorized. Reinitialize: Force

Strona 184

264 4.11.4 Network Access Overview This Page provides an overview of the current NAS port state

Strona 185 - 4.8.13 MLD Snooping Status

265 is not overridden by NAS. If the VLAN ID is assigned by the RADIUS server, "(RADIUS-as

Strona 186 - 4.8.14 MLD Group Information

266  QoS Class The QoS class assigned by the RADIUS server. The field is blank if no QoS clas

Strona 187 - 4.8.15 MLDv2 Information

267 mesRx frames that have been received by the switch. Rx Logoff dot1xAuthEapolLogoffFramesRx

Strona 188

268 MAC-based Auth. Direction Name IEEE Name Description Rx Access Challenges dot1xAuth

Strona 189

269 Failures Fails Counts the number of times that the switch receives a failure message. This

Strona 190

27 Connection to the Managed Switch requires UTP Category 5e network cabling with RJ-45 tips.

Strona 191

270 Address rameSource VLAN ID - The VLAN ID on which the last frame from the last supplicant/

Strona 192 - 4.8.17 MVR Status

271 Selected Counters Object Description  Selected Counters The Selected Counters table is v

Strona 193

272 : This button is available in the following modes: • Force Authorized • Force Unauthorized

Strona 194 - 4.8.19 MVR SFM Information

273 Figure 4-11-7: RADIUS Server Configuration Page Screenshot The Page includes the followin

Strona 195

274  Key The secret key - up to 63 characters long - shared between the RADIUS server and the

Strona 196 - 4.9 Quality of Service

275 : Click to undo the addition of the new server. : Click to apply changes : Click to undo

Strona 197 - 4.9.2 Port Policing

276 trying to contact a server that it has already determined as dead. Setting the Deadtime to

Strona 198 - 4.9.3 Port Classification

277 4.11.8 RADIUS Overview This Page provides an overview of the status of the RADIUS servers c

Strona 199

278 been disabled, but will get re-enabled when the dead-time expires. The number of seconds le

Strona 200 - 4.9.4 Port Scheduler

279 4.11.9 RADIUS Details This Page provides detailed statistics for a particular RADIUS server

Strona 201 - 4.9.5 Port Shaping

28 Step 5: After the brackets are attached to the Managed Switch, use suitable screws to secure

Strona 202

280 counters. Direction Name RFC4668 Name Description Rx Access Accepts radiusAuthClientExtA

Strona 203 - 4.9.6 Port Tag Remarking

281 dropped for some other reason. Rx Packets Dropped radiusAuthClientExtPacketsDropped The num

Strona 204

282 counted as a retransmit as well as a timeout. A send to a different server is counted as a

Strona 205

283 between the backend servers to show details for. Object Description RADIUS accounting serv

Strona 206 - 4.9.7 Port DSCP

284 Tx Retransmissions radiusAccClientExtRetransmissions The number of RADIUS packets retransmi

Strona 207

285 accounting attempts.  Dead (X seconds left): Accounting attempts were made to this server

Strona 208 - 4.9.8 DSCP-based QoS

286 Figure 4-11-11: RADIUS Server Configuration Screenshot

Strona 209 - Drop Precedence Level (0-1)

287 2. Add New RADIUS Cleint on the Windows 2003 server Figure 4-11-12: Windows Server – Add

Strona 210 - 4.9.9 DSCP Translation

288 Figure 4-11-13: Windows Server RADIUS Server Setting 4. The shared secret key should be as

Strona 211 - 4.9.10 DSCP Classification

289 5. Configure ports attribute of 802.1X, the same as “802.1X Port Configuration”. Figure

Strona 212 - 4.9.11 QoS Control List

29  Approved IFS SFP Transceivers NS3702 Managed Switch supports both single mode and m

Strona 213

290 Figure 4-11-17: Add User Properties Screen Figure 4-11-18: Add User Properties Screen

Strona 214

291 Set the Port Authenticate Status to “Force Authorized” if the port is connected to the RAD

Strona 215

292 4. Select “Authentication” tab. 5. Select “Enable network access control using IEEE 802.

Strona 216 - 4.9.12 QCL Status

293 Figure 4-11-21: Windows Client Popup Login Request Message 9. Enter the user name, passwo

Strona 217

294 4.12 Security This section is to control the access of the Managed Switch, includes the use

Strona 218

295 Figure 4-12-1: Port Limit Control Configuration Overview Page Screenshot The Page include

Strona 219

296  Aging Period If Aging Enabled is checked, then the aging period is controlled with this

Strona 220 - 4.9.14 WRED

297 available MAC addresses.  Action If Limit is reached, the switch can take one of the foll

Strona 221

298 non-committed changes will be lost.

Strona 222 - 4.9.15 QoS Statistics

299 Buttons : Click to apply changes : Click to undo any changes made locally and revert to p

Strona 223

3 TABLE OF CONTENTS 1. INTRODUCTION...

Strona 224

30 1. It is recommended to use IFS SFPs on the Managed Switch. If you insert an SFP transceiv

Strona 225

300 host IP address matched the entry.  SNMP Indicates the host can access the switch from SN

Strona 226 - 4.9.17 Voice VLAN OUI Table

301 Buttons Auto-refresh : Check this box to refresh the Page automatically. Automatic refres

Strona 227 - : Click to apply changes

302 4.12.4 HTTPs Configure HTTPS on this Page. The HTTPS Configuration screen in Figure 4-12-4

Strona 228 - 4.10 Access Control Lists

303 port is set-up for software-based learning. In this mode, frames from unknown MAC addresses

Strona 229

304 Figure 4-12-6: Port Security Status Screen Page Screenshot The Page includes the followin

Strona 230

305 Object Description  Port The port number for which the status applies. Click the port nu

Strona 231

306 4.12.7 Port Security Detail This Page shows the MAC addresses secured by the Port Security

Strona 232 - 4.10.3 ACE Configuration

307 4.12.8 DHCP Snooping DHCP Snooping is used to block intruder on the untrusted ports of DUT

Strona 233

308 Figure 4-12-8: DHCP Snooping Configuration Screen Page Screenshot The Page includes the fo

Strona 234 -  VLAN Parameters

309 : Click to apply changes : Click to undo any changes made locally and revert to previousl

Strona 235

31 Figure 2-2-5: How to Pull Out the SFP/SFP+ Transceiver Never pull out the module without

Strona 236 -  IP Parameters

310 Figure 4-12-10: IP Source Guard Configuration Screen Page Screenshot The Page includes th

Strona 237 - IPv4 frame

311 that are matched in static entries on the specific port. Buttons : Click to translate all

Strona 238 -  IPv6 Parameters

312 4.12.12 ARP Inspection ARP Inspection is a secure feature. Several types of attacks can be

Strona 239 -  ICMP Parameters

313 The Page includes the following fields: Object Description  Mode of ARP Inspection Confi

Strona 240 -  TCP/UDP Parameters

314 4.12.13 ARP Inspection Static Table This Page provides Static ARP Inspection Table. The Sta

Strona 241

315 4.13 Address Table Switching of frames is based upon the DMAC address contained in the fram

Strona 242 -  Ethernet Type Parameters

316 Aging Configuration By default, dynamic entries are removed from the MAC table after 300 se

Strona 243

317 Buttons : Click to apply changes : Click to undo any changes made locally and revert to p

Strona 244

318 The Page includes the following fields: Object Description  Type Indicates whether the

Strona 245

319 Page" input field. When first visited, the web Page will show the first 20 entries fro

Strona 246 - 4.11 Authentication

32 3. SWITCH MANAGEMENT This chapter explains the methods that you can use to configure managem

Strona 247

320 Figure 4-13-4: Dynamic IP Source Guard Table Screenshot Navigating the ARP Inspection Tab

Strona 248

321 Buttons Auto-refresh : Check this box to refresh the Page automatically. Automatic refresh

Strona 249

322 4.14 LLDP 4.14.1 Link Layer Discovery Protocol Link Layer Discovery Protocol (LLDP) is us

Strona 250

323 Figure 4-14-1: LLDP Configuration Page Screenshot The Page includes the following fields: L

Strona 251

324  Port The switch port number of the logical LLDP port.  Mode Select LLDP mode.  Rx

Strona 252

325  System Description Optional TLV: When checked the "system description" is incl

Strona 253 - System Configuration

326 The Page includes the following fields: Fast start repeat count Object Description  Fas

Strona 254

327 Object Description  Latitude Latitude SHOULD be normalized to within 0-90 degrees with a

Strona 255

328 or US.  State National subdivisions (state, canton, region, province, prefecture).  Cou

Strona 256 - Port Configuration

329 Emergency Call Service (e.g. E911 and others), such as defined by TIA or NENA. Object Desc

Strona 257

33 3.2 Management Access Overview The Managed Switch gives you the flexibility to access and ma

Strona 258

330 LAN. Object Description  Delete Check to delete the policy. It will be deleted during th

Strona 259

331 applications relying on TCP with buffering would not be an intended use of this application

Strona 260

332 Object Description  Port The port number for which the configuration applies.  Policy

Strona 261

333 Devices. An LLDP-MED Network Connectivity Device is a LAN access device based on any of the

Strona 262

334 LLDP-MED Communication Endpoint (Class III) The LLDP-MED Communication Endpoint (Class II

Strona 263

335  Video Conferencing - for use by dedicated Video Conferencing equipment and other similar

Strona 264

336  Auto-negotiation Capabilities Auto-negotiation Capabilities shows the link partners MAC/

Strona 265 - Port State

337 4. WLAN Access Point 5. Router 6. Telephone 7. DOCSIS cable device 8. Station only 9. Reser

Strona 266 - Port Counters

338 Figure 4-14-5: LLDP Statistics Page Screenshot The Page includes the following fields: Gl

Strona 267

339 The displayed table contains a row for each port. The columns hold the following informatio

Strona 268

34 3.3 Administration Console The administration console is an internal, character-oriented, an

Strona 269

340 4.15 Network Diagnostics This section provide the Physical layer and IP layer network diagn

Strona 270

341 4.15.1 Ping This Page allows you to issue ICMP PING packets to troubleshoot IP connectivity

Strona 271 - Attached MAC Address

342 4.15.2 IPv6 Ping This Page allows you to issue ICMPv6 PING packets to troubleshoot IPv6 con

Strona 272 - 4.11.6 RADIUS

343 4.15.3 Remote IP Ping Test This Page allows you to issue ICMP PING packets to troubleshoot

Strona 273 - Global Configuration

344 : Click to undo any changes made locally and revert to previously saved values. : Clears th

Strona 274

345 The Page includes the following fields: Object Description  Port The port where you are

Strona 275 - 4.11.7 TACACS+

346 4.16 Power over Ethernet Providing up to 24 PoE, in-line power interfaces, the NS3702-24P-4

Strona 276

347 3~12 Watts PoE Splitter PoE Splitter split the PoE 52V DC over the Ethernet cable into 5/1

Strona 277 - 4.11.8 RADIUS Overview

348  Classification mode In this mode each port automatic determines how much power to reserv

Strona 278

349 Figure 4-16-2: PoE Configuration Screenshot

Strona 279 - 4.11.9 RADIUS Details

35 connected and monitor the system during system reboots. Also, certain error messages are sen

Strona 280

350 The page includes the following fields: Object Description  System PoE Admin Mode Allows

Strona 281

351 A PD will return to Class 0 to 4 in accordance with the maximum power draw as specified by

Strona 282

352 Buttons : Click to apply changes : Click to undo any changes made locally and revert to

Strona 283

353  Disable: disable PoE function.  Schedule: enable PoE function in schedule mode.  Sch

Strona 284

354 4.16.6 PoE Status This page allows the user to inspect the total power consumption, total p

Strona 285

355 Figure 4-16-5:PoE Status Screenshot

Strona 286

356 The page includes the following fields: Object Description  Sequential Power On Displays

Strona 287

357 4.16.7 PoE Schedule This page allows the user to define PoE schedule and schedule power rec

Strona 288

358 The screen in Figure 4-16-6 appears. Figure 4-16-6: PoE Schedule Screenshot Please press

Strona 289

359 Object Description  Profile Set the schedule profile mode. Possible profiles are:  Pro

Strona 290

36 3.5 SNMP-based Network Management You can use an external SNMP-based application to config

Strona 291

360 Figure 4-16-7: LLDP PoE Neighbour Screenshot Please be noticed that administrator has to

Strona 292

361 This page provides you with how to configure PD Alive Check.The screen in Figure 4-16-9 ap

Strona 293

362  Reboot & Alarm: It means system will reset the PoE port and issue an alarm message vi

Strona 294 - 4.12 Security

363 4.16.10 Port Power Consumption This page allows user to see the usage of individual PoE Por

Strona 295

364 4.17 Loop Protection This chapter describes enabling loop protection function that provides

Strona 296

365 The Page includes the following fields: General Settings Object Description  Enable Loop

Strona 297

366 4.17.2 Loop Protection Status This Page displays the loop protection port status of the swi

Strona 298

367 4.18 RMON RMON is the most important expansion of the standard SNMP. RMON is a set of MIB d

Strona 299 - 4.12.2 Access Management

368  InUcastPkts: The number of uni-cast packets delivered to a higher-layer protocol.  InN

Strona 300

369 : Click to add a new community entry. : Click to apply changes : Click to undo any change

Strona 301

37 4. WEB CONFIGURATION This section introduces the configuration and functions of the Web-base

Strona 302 - 4.12.5 SSH

370 : Click to refresh the Page immediately. Auto-refresh : Check this box to refresh the Page

Strona 303 - 4.12.6 Port Security Status

371 Buttons : Click to add a new community entry. : Click to apply changes : Click to undo an

Strona 304

372 4.18.4 RMON Event Status This Page provides an overview of RMON Event table entries.Each Pa

Strona 305

373 4.18.5 RMON History Configuration Configure RMON History table on this Page. The entry inde

Strona 306 - 4.12.7 Port Security Detail

374 4.18.6 RMON History Status This Page provides an detail of RMON history entries; screen in

Strona 307 - 4.12.8 DHCP Snooping

375  Jabb. The number of frames which size is larger than 64 octets received with invalid CR

Strona 308

376 Buttons : Click to add a new community entry. : Click to apply changes : Click to undo an

Strona 309 - 4.12.9 Snooping Table

377 but including FCS octets) of between 64 and 1518 octets.  Undersize The total number of p

Strona 310

378 5. SWITCH OPERATION 5.1 Address Table The Managed Switch is implemented with an address tab

Strona 311

379 The Managed Switch performs "Store and Fforward" therefore, no error packets oc

Strona 312 - 4.12.12 ARP Inspection

38 2. When the following login screen appears, please enter the default username "admin&q

Strona 313

380 6. Power over Ethernet Overview What is PoE? The PoE is an abbreviation of Power over Ether

Strona 314

381 specification allows two options for using these cables for power, shown in Figure 1 and Fi

Strona 315 - 4.13 Address Table

User’s Manual of NS3702-24P-4S 7. TROUBLESHOOTING This chapter contains information to help you solve issues. If the Managed Switch is not functionin

Strona 316

User’s Manual of NS3702-24P-4S APPENDIX A: Networking Connection A.1 PoE RJ-45 Port Pin Assignments PIN NO RJ-45 POWER ASSIGNMENT 1  Power + 2  P

Strona 317 - Navigating the MAC Table

User’s Manual of NS3702-24P-4S A.3 10/100Mbps, 10/100Base-TX When connecting your Switch to another Fast Ethernet switch, a bridge or a hub, a straig

Strona 318

User’s Manual of NS3702-24P-4S The standard cable, RJ-45 pin assignment 2 1 3 6 12362 1 3 6 The standard RJ-45 receptacle/connector There are 8

Strona 319

386 APPENDIX B : GLOSSARY A ACE ACE is an acronym for Access Control Entry. It describes acc

Strona 320

387 See the Web Page help text for each specific port property. ACL|Rate Limiters: Under this

Strona 321

388 Auto-Negotiation Auto-negotiation is the process where two different devices establish th

Strona 322 - 4.14 LLDP

389 DHCP used by networked computers (clients) to obtain IP addresses and other parameters such

Strona 323 - LLDP Port Configuration

39 Figure 4-1-3: Web Main Page Now, you can use the Web management interface to continue the

Strona 324

390 DoS is an acronym for Denial of Service. In a denial-of-service (DoS) attack, an attacker a

Strona 325

391 HTTP HTTP is an acronym for Hypertext Transfer Protocol. It is a protocol that used to tr

Strona 326 - Coordinates Location

392 credentials for authentication from any point within the network. IGMP IGMP is an acron

Strona 327

393 IPMC is an acronym for IP MultiCast. IP Source Guard IP Source Guard is a secure feature u

Strona 328 - Emergency Call Service

394 administrator wants to do a fixed mapping between the DMAC address and switch ports. The

Strona 329 - Policies

395 credentials are valid. Based on the answer, the NAS then allows or disallows access to the

Strona 330

396 OUI is the organizationally unique identifier. An OUI address is a globally unique identifi

Strona 331

397 An alternative protocol is Internet Message Access Protocol (IMAP). IMAP provides the user

Strona 332 - 4.14.4 LLDP-MED Neighbor

398 Q QCE QCE is an acronym for QoS Control Entry. It describes QoS class associated with a

Strona 333

399 R RARP RARP is an acronym for Reverse Address Resolution Protocol. It is a protocol that

Strona 334

4 4.2.2 IP Configuration...

Strona 335

40 4.1 Main Web Page The Managed Switch provides a Web-based browser interface for configuring

Strona 336 - 4.14.5 Neighbor

400 (known as a message digest) of an input data sequence (the message) of any length. Shaper

Strona 337 - 4.14.6 Port Statistics

401 strong authentication or guarantee confidentiality (Wikipedia). SSM SSM In SyncE this is

Strona 338 - Global Counters

402 TELNET is an acronym for TELetype NETwork. It is a terminal emulation protocol that uses th

Strona 339

403 UDP provides two services not provided by the IP layer. It provides port numbers to help di

Strona 340 - 4.15 Network Diagnostics

404 W WEP WEP is an acronym for Wired Equivalent Privacy. WEP is a deprecated algorithm to sec

Strona 341 - 4.15.1 Ping

405 (Wikipedia). WRES WRED is an acronym for Weighted Random Early Detection. It is an active

Strona 342 - 4.15.2 IPv6 Ping

41 those listed in the Main Function. The screen in Figure 4-1-5 appears. Figure 4-1-5: Manage

Strona 343 - 4.15.3 Remote IP Ping Test

42 4.2 System Use the System menu items to display and configure basic administrative details o

Strona 344 - 4.15.4 Cable Diagnostics

43 4.2.1 System Information The System Infomation Page provides information for the current dev

Strona 345

44  Software Version The software version of the Managed Switch.  Software Date The date wh

Strona 346 - 4.16 Power over Ethernet

45 mode traffic is routed between all interfaces. DNS Server This setting controls the DNS na

Strona 347 - 4.16.2 System Configuration

46 Mask Length The destination IP network or host mask, in number of bits (prefix length). Gate

Strona 348

47 Figure 4-2-3: IP Status Page Screenshot The Page includes the following fields: Object Desc

Strona 349

48 refer to each group privilege level. User's privilege should be same or greater than th

Strona 350

49 groups, i.e. that is granted the fully control of the device. But others value need to refer

Strona 351 - 4.16.4 Port Sequential

5 4.4.1 Port Configuration...

Strona 352 - 4.16.5 Port Configuration

50 If you forget the new password after changing the default password, please press the “Rese

Strona 353

51 4.2.5 Privilege Levels This Page provides an overview of the privilege levels. After setup i

Strona 354 - 4.16.6 PoE Status

52 The Page includes the following fields: Object Description  Group Name The name identif

Strona 355

53 4.2.6 NTP Configuration Configure NTP on this Page. NTP is an acronym for Network Time Proto

Strona 356

54 4.2.7 Time Configuration Configure Time Zone on this Page. A Time Zone is a region that has

Strona 357 - 4.16.7 PoE Schedule

55 to identify the time zone. ( Range : Up to 16 characters )  Daylight Saving Time This is

Strona 358

56 Figure 4-2-10: UPnP Configuration Page Screenshot The Page includes the following fields:

Strona 359 - 4.16.8 LLDP PoE Neighbours

57 Figure 4-2-11: UPnP devices show on Windows My Network Place 4.2.9 DHCP Relay Configure

Strona 360

58 screen in Figure 4-2-12 appears. Figure 4-2-12 DHCP Relay Configuration Page Screenshot Th

Strona 361

59  Drop: Drop the package when receiving a DHCP message that already contains relay informat

Strona 362

6 4.7.9 Port Statistics...

Strona 363

60  Receive Bad Circuit ID The packets number that the Circuit ID option did not match known

Strona 364 - 4.17 Loop Protection

61 4.2.11 CPU Load This Page displays the CPU load, using a SVG graph. The load is measured as

Strona 365 - General Settings

62 4.2.12 System Log The Managed Switch system log information is provided here. The System Log

Strona 366

63 : Hides the selected log entries. : Downloads the selected log entries. : Updates the system

Strona 367 - 4.18 RMON

64 : Updates the system log entry to the previous available entry ID. : Updates the system log

Strona 368

65 Buttons : Click to apply changes : Click to undo any changes made locally and revert to pr

Strona 369 - 4.18.2 RMON Alarm Status

66 4.2.15 SMTP Configuration This Page facilitates an SMTP Configuration on the switch. The SMT

Strona 370

67 Buttons : Send a test mail to mail server to check this account is available or not. : Clic

Strona 371

68 DO NOT Power OFF the Managed Switch until the update progress is complete. Do not quit th

Strona 372 - 4.18.4 RMON Event Status

69 Do not quit the Firmware Upgrade Page without pressing the “OK” button after the image is l

Strona 373

7 4.9.12 QCL Status ...

Strona 374 - 4.18.6 RMON History Status

70 Figure 4-2-24: Configuration Download Page Screenshot 4.2.20 Configuration Upload Configura

Strona 375 - Index and Sample Index

71 4.2.21 Configuration Activate Configuration Activate page allows to activate the startup-co

Strona 376

72 4.2.23 Image Select This Page provides information about the active and alternate (backup)

Strona 377

73 Object Description  Image The flash index name of the firmware image. The name of primary

Strona 378 - 5. SWITCH OPERATION

74 Figure 4-2-30: System Reboot Page Screenshot Buttons : Click to reboot the system. : Click

Strona 379 - 5.5 Auto-Negotiation

75 SNMP Operations SNMP itself is a simple request/response protocol. NMSs can send multiple

Strona 380 - What is PoE?

76 4.3.2 SNMP System Configuration Configure SNMP on this Page. The SNMP System Configuration s

Strona 381

77 SNMP version is SNMPv3, the community string will be associated with SNMPv3 communities tabl

Strona 382 - 7. TROUBLESHOOTING

78 4.3.3 SNMP Trap Configuration Configure SNMP trap on this Page. The SNMP Trap Configuration

Strona 383 - - 1000Mbps, 1000Base-T

79  Trap Community Indicates the community access string when send SNMP trap packet. The allo

Strona 384

8 4.12.12 ARP Inspection ...

Strona 385 - 12345678

80  System Enable/disable that the Interface group's traps. Possible traps are:  Warm

Strona 386 - APPENDIX B : GLOSSARY

81  System Name An administratively assigned name for this managed node. By convention, this

Strona 387

82 SNMPv1 or SNMPv2c community string.  Source IP Indicates the SNMP access source address. A

Strona 388

83 engine with which this user can communicate. In other words, if user engine ID equal system

Strona 389

84 : Click to add a new user entry. : Click to apply changes : Click to undo any changes made

Strona 390

85 : Click to apply changes : Click to undo any changes made locally and revert to previously

Strona 391

86 : Click to undo any changes made locally and revert to previously saved values. 4.3.5.5 SNM

Strona 392

87  Write View Name The name of the MIB view defining the MIB objects for which this request

Strona 393

88 4.4 Port Management Use the Port Menu to display or configure the Managed Switch's port

Strona 394

89 red that it is down.  Current Link Speed Provides the current link speed of the port.  C

Strona 395

9 4.18.1 RMON Alarm Configuration ...

Strona 396

90 4.4.2 Port Statistics Overview This Page provides an overview of general traffic statistic

Strona 397

91 4.4.3 Port Statistics Detail This Page provides detailed traffic statistics for a specific s

Strona 398

92  Rx and Tx Broadcast The number of received and transmitted (good and bad) broadcast packe

Strona 399

93 : Clears the counters for all ports. Auto-refresh : Check this box to enable an automatic

Strona 400

94  Distance(m) Display the supports distance of current SFP module, the distance value is ge

Strona 401

95 Figure 4-4-7: Port Mirror Application The traffic to be copied to the mirror port is selec

Strona 402

96 Figure 4-4-8: Mirror Configuration Page Screenshot The Page includes the following fields:

Strona 403

97 Buttons : Click to apply changes : Click to undo any changes made locally and revert to pr

Strona 404

98 Figure 4-5-1: Link Aggregation The Link Aggregation Control Protocol (LACP) provides a stan

Strona 405

99  Enable the link aggregation prior to connecting any cable between the switches to avoid c

Komentarze do niniejszej Instrukcji

Brak uwag