1RWHRefer to specific sensor installation instructions for complete
operation and testing details.
&HQWUDOVWDWLRQFRPPXQLFDWLRQ
After performing sensor tests, check that the system is reporting
alarms successfully to the central station.
7RWHVWFRPPXQLFDWLRQZLWKWKHFHQWUDOVWDWLRQ
1. Call the central station and tell the operator that you will be
testing the system.
2. Arm the system.
3. Test each of the wireless panic buttons and trip at least one
sensor of each type (fire, intrusion, etc.) to verify that the
appropriate alarms are working correctly.
There is a 30 second delay.
4. When you finish testing the system, call the central station to
verify that the alarms were received.
6SHFLILFDWLRQV
Power 9 VAC, 60 Hz, 25 VA transformer minimum
Rechargeable battery: 6.0 VDC, 1.2 Ah lead-acid.
The battery will last 24 hours with no AC and
specified standby load of 250 mA. Maximum
battery charging current is 45 mA. With loss of
AC, panel will continue to operate normally to a
minimum of 5.1 VDC.
Radio frequency 319.5 MHz
Storage temperature -29 to 140ºF (-34 to 60ºC)
Operating
temperature
32 to 120ºF (0 to 49ºC)
Maximum humidity 85% relative humidity, noncondensing
Auxiliary power Unregulated 5.3 to 12.3 VDC, with a maximum of
250 mA
5HJXODWRU\LQIRUPDWLRQ
8/OLVWHGLQVWDOODWLRQV
Some installation may require configurations dictated by
city/state codes, insurance, or Underwriter’s Laboratories (UL). This
section describes the various component and configuration
listings.
Basic system:
Control panel: Backup battery 6 V 1.2 Ah (34-025) (Portalac
model # PE6V1.2)
Standard class 2, 9 VAC, 3.34 A power transformer (part 22-
153). Alternate transformer for US installations: MG
Electronics model MGT925, 9 VAC, 25 VA, (part 22-155)
Hardwired siren (13-374)
Household burglary alarm system unit (UL 1023), basic system
plus the following:
Hardwired magnetic contact (13-068 or 13-071) or wireless
learn mode door/window sensor (60-670)
Panel piezo beeps set to on
Entry delay set to 45 seconds or less
Exit delay set to 60 seconds or less
RF time-out set to 24 hours
Control panel alarms turned on
Auto arm set to on
Siren timeout set to 5 minutes or more
Trouble beeps set to on
RF jam detect set to on
Hardwired siren supervision set to on
Exit extension set to off
Quick exit set to off
Household fire warning system (UL 985), basic system plus the
fo
llowing:
Wireless smoke sensor 60-848-02-95, TX-6010-01-1 learned
into sensor group 26.
Panel piezo beeps turned on
Control panel alarms set to on
Siren timeout set to 4 minutes or more
Trouble beeps set to on
RF jam detect set to on
Hardwired siren supervision set to on
Smoke supervision set to on
UL 1023 and 985 24-hour backup:
For 24-hour backup, the total current draw for all connected
devices is limited to 240 mA (during normal standby
conditions) using a 1.2 AH battery.
UL 1635 digital alarm communicator system (same as UL 1023
and 985) plus the following settings are in addition to UL 1023 and
985 and are required only if the system is set up for central station
reporting:
Phone mod 1 set to 0 or 1
Automatic phone test set to 001
RF timeout set to 4 hours
AC power failure report set to on
CPU low battery report set to on
Fail to communicate set to on
Entry delay plus the dialer delay must not exceed 60 seconds