1138T Series Magnetic Contacts
Surface Mount Terminal
Installation Instructions
Step 1: Run the system wiring to the switch location.
Step 2: Align and mount the switch and the magnet with either the tape or screws
provided. Orient as shown in the drawing below.
Step 3: Insert wires through the wire lead entrances into the screw terminals.
Tighten the screws.
FORM A 1138T
Voltage: 30VAC/DC MAX
Current: 0.5A MAX
Power: 7.5W MAX
Use only wire sizes 18-22 gauge
Specifications
1035748 REV B 09/01
Switch
Magnet
Wire lead entrances
Part Loop Electrical Gap Distance
Number Type Configuration
1138T Closed NO Nominal 1"
Min Make 0.8"
Max Break 2.2"