Interlogix XL LCD Keypad Plus User Guide Instrukcja Użytkownika Strona 1

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Bezpieczeństwo Interlogix XL LCD Keypad Plus User Guide. Interlogix XL LCD Keypad Plus User Guide User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 54
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
LCD Keypad User's Guide
rev1.3
Attention: Security Representative / Installer,
Please give this guide to the customer before beginning work on the system.
Przeglądanie stron 0
1 2 3 4 5 6 ... 53 54

Podsumowanie treści

Strona 1 - LCD Keypad User's Guide

LCD Keypad User's Guide rev1.3 Attention: Security Representative / Installer, Please give this guide to the customer before beg

Strona 2

2 xL LCD Keypad User's Guide 21-3600E rev1.3 1,- #2ABC3DEF45JKL6MNOGHI78TUV9WXYPRS0Z_QXXKeypad LightsRed Flashing: Protection ON Solid: Partial

Strona 3 - Contents

21-3600E rev1.3 Welcome Alarm Status Admin Reference 3 If You Are Being Forced to Enter Protected Premises A duress (panic) alarm is triggered when

Strona 4

4 xL LCD Keypad User's Guide 21-3600E rev1.3 Test: This allows testing different aspects of the system. Verify: This allows a person to prove

Strona 5 - Also See (Related Documents)

21-3600E rev1.3 Welcome Alarm Status Admin Reference 5 Alarms, Turning Protection On and Off

Strona 6 - WARNING NOTICE:

6 xL LCD Keypad User's Guide 21-3600E rev1.3 Alarm Monitoring Features Depending on how the system is set up, specific alarms may be indicated

Strona 7 - CE – Conformity

21-3600E rev1.3 Welcome Alarm Status Admin Reference 7 Sirens Conventional Siren Fire Alarm: Intermittent Tone (the same as a Fire Alarm in the pr

Strona 8

8 xL LCD Keypad User's Guide 21-3600E rev1.3 Using the Emergency Keys There are three emergency keys that will cause an emergency alarm. This

Strona 9 - Welcome

21-3600E rev1.3 Welcome Alarm Status Admin Reference 9 Suspending Schedules for an Area or Areas A schedule can be blocked altogether if you do not

Strona 10 - The xL LCD Keypad

10 xL LCD Keypad User's Guide 21-3600E rev1.3 Select View to view points that are currently bypassed or not Ok. At this time the system will i

Strona 11 - Overview of Screens (Topics)

21-3600E rev1.3 Welcome Alarm Status Admin Reference 11 Area Priority Protection On/Off Priority Arming requires that areas are armed and disarmed i

Strona 13 - Protection On

12 xL LCD Keypad User's Guide 21-3600E rev1.3 UK System Operation The following is required to ensure conformity with the ACPO, DD243:2002 Stan

Strona 14 - Audible Keypad Tones

21-3600E rev1.3 Welcome Alarm Status Admin Reference 13 To view the armed state of the system, log in from the “Enter ID:” screen. If all areas are

Strona 15 - Silencing a False Alarm

14 xL LCD Keypad User's Guide 21-3600E rev1.3 #

Strona 16 - -> 09:30pMo

21-3600E rev1.3 Welcome Alarm Status Admin Reference 15 Checking Status and Controlling Items

Strona 17 - Area or Areas

16 xL LCD Keypad User's Guide 21-3600E rev1.3 Status and Control Features NOTE: Status will display certain options e.g. “Comms, Modem, Licns”

Strona 18 - Individual Areas

21-3600E rev1.3 Welcome Alarm Status Admin Reference 17 Checking the Status of Sensors (Points) and Areas The Points-status feature allows checking

Strona 19

18 xL LCD Keypad User's Guide 21-3600E rev1.3 1. Select Bypass. 2. Select an area and “Pts” to view Points in that area. 3. Select “Cmd”

Strona 20 - Operation

21-3600E rev1.3 Welcome Alarm Status Admin Reference 19 selections that follow. 9. Your Cmd choices are shown below: • Mode: Access modes includi

Strona 21

20 xL LCD Keypad User's Guide 21-3600E rev1.3 #

Strona 22 - 21-3600E rev1.3

21-3600E rev1.3 Welcome Alarm Status Admin Reference 21 Administration and Maintenance Tasks

Strona 23 - Checking Status

21-3600E rev1.3 (4.6.2008) © 2008 CSG Security Inc. / Sécurité CSG Inc. i For topics not listed here, please see the Index Welcome

Strona 24 - Checking the System Status

22 xL LCD Keypad User's Guide 21-3600E rev1.3 Changing Your Own PIN The person who is logged in can change their PIN number at any time. Step

Strona 25 - (Points) and Areas

21-3600E rev1.3 Welcome Alarm Status Admin Reference 23 Default Authority Settings Intrusion Master Supervisor Employee Worker Cleaner Emergency O

Strona 26 - Readers or Doors

24 xL LCD Keypad User's Guide 21-3600E rev1.3 System / Suite (Condo): For systems with Suite Security keypads, this screen allows accessing t

Strona 27 - Application Module (POD)

21-3600E rev1.3 Welcome Alarm Status Admin Reference 25 4. Select Edit. ↓?: refers to systems with Suite Security (Condo) keypads (allows viewing

Strona 28

26 xL LCD Keypad User's Guide 21-3600E rev1.3 Deleting a User Users can be deleted from the system when necessary. To allow tracking card-usage

Strona 29 - Administration

21-3600E rev1.3 Welcome Alarm Status Admin Reference 27 Manually calling the Director PC from the LCD Keypad: • This operation is for systems that

Strona 30 - Adding a User to the System

28 xL LCD Keypad User's Guide 21-3600E rev1.3 Printing the History Log If your system includes a printer-capable module, you can print the hist

Strona 31

21-3600E rev1.3 Welcome Alarm Status Admin Reference 29 Testing Monitored Sensors (Performing a Walk Test) A Walk Test allows you to test specif

Strona 32 - 3. Enter the specific

30 xL LCD Keypad User's Guide 21-3600E rev1.3 Testing Panic Buttons (Performing a Hold-up Test) UL Listed Systems: Not evaluated to UL636 –Hol

Strona 33 - 4. Select Edit

21-3600E rev1.3 Welcome Alarm Status Admin Reference 31 Reference Topics

Strona 34 - Setting the Date and Time

ii xL LCD Keypad User's Guide 21-3600E rev1.3 Residential Fire Safety / Evacuation Plan...

Strona 35 - ” will appear between the

32 xL LCD Keypad User's Guide 21-3600E rev1.3 Your alarm system has specific information. This information should be recorded below at the tim

Strona 36 - Language

21-3600E rev1.3 Welcome Alarm Status Admin Reference 33 System Details: Entry and Exit Delays: Entry Delay:_______ Exit Delay:_______ Misc

Strona 37 - (Performing a Walk Test)

34 xL LCD Keypad User's Guide 21-3600E rev1.3 No fire detection system should be considered 100 percent foolproof. This fire alarm system can

Strona 38 - (Performing a Hold-up Test)

21-3600E rev1.3 Welcome Alarm Status Admin Reference 35 thin layer on the floor. • If you live in a high-rise building, use the stairs — never th

Strona 39 - Reference

36 xL LCD Keypad User's Guide 21-3600E rev1.3 (option) The optional Arming Station allows many system tasks to be performed without having to

Strona 40 - System Information

21-3600E rev1.3 Welcome Alarm Status Admin Reference 37 Command Result # # Cancels any keys previously entered. Command Result # If performing a

Strona 41 - Function Key Reference

38 xL LCD Keypad User's Guide 21-3600E rev1.3 xL Arming Station Lights The optional xL Arming Station has three lights to indicate door, system

Strona 42 - Practicing Fire Safety

21-3600E rev1.3 Welcome Alarm Status Admin Reference 39 Not evaluated by UL xL Wireless Keypad (option) The optional xL Wireless Handheld Keypad a

Strona 43 - Messages for young children

40 xL LCD Keypad User's Guide 21-3600E rev1.3 Keypad Screen Display Error Messages This section contains a list of error messages that may appe

Strona 44 - Arming Station Reference

21-3600E rev1.3 Welcome Alarm Status Admin Reference 41 Things to Do to Prevent False Alarms Please do your part to prevent false alarms. This ens

Strona 45 - #" key between

21-3600E rev1.3 xL LCD Keypad User's Guide iii About This Guide This guide provides details on performing various tasks in a x

Strona 46

42 xL LCD Keypad User's Guide 21-3600E rev1.3 Access Token ON, OFF...11 ACPO Confirmed Alarm Remote Reset ...

Strona 47 - Wireless Keypad Reference

21-3600E rev1.3 Welcome Alarm Status Admin Reference 43 Sensor, bypassing ...17 Sensors (points), checking t

Strona 51

iv xL LCD Keypad User's Guide 21-3600E rev1.3 installed, it is the responsibility of the installing company to ensure that the jack and/or plug

Strona 52

21-3600E rev1.3 xL LCD Keypad User's Guide v CE – Conformity The xL System described in this manual conforms to the requiremen

Strona 54

21-3600E rev1.3 Welcome Alarm Status Admin Reference 1 Dear Customer, • It is recommended that you review the different operating p

Komentarze do niniejszej Instrukcji

Brak uwag