Interlogix 5600 Series Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Czujniki Interlogix 5600 Series. Interlogix 5600 Series User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 4
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
1
ShatterPoint Glassbreak Sensor
Mounting
Description
The 5600 Glassbreak Sensors are designed to detect
breaking glass caused by forced entry into a protected
window or door. The ‘Tru-Dual’ transducer design provides
excellent false-alarm immunity in noisy environments.
The 5600 Sensors process both acoustic and vibration
information to identify breaking windows. Frame mounting
the 5600 Sensors eliminates detection concerns with drapes
and blinds. The built-in reed switch models provide
protection against forced opening of windows or doors, as
well as breaking glass.
Note These sensors may not consistently detect
cracks, bullets, or similar breaks. Glassbreak sensors
should always be backed up by interior protection such
as a motion detector.
Figure 1a. Frame Mounting
The 5600 sensors are designed to mount either inside the
frame (see Figure 1a) or on the facing (see Figure 1b). Refer
to Figure 3 for recommended mounting locations and
coverage range. The mounting location should provide good
mechanical coupling from glass to sensor and an
unobstructed microphone view of the glass. If structural
integrity of the frame is poor, temporarily mount the sensor
and follow the steps in Testing for range testing. Do not
exceed the tested range of the sensor.
Note For applications with more than one framed
window, use multiple 5600s or a ShatterPro II.
Use the screws provided to mount the sensor securely to the
frame. A loosely mounted sensor will not perform correctly.
The small cover screw must be used to permanently attach
the cover (see Figure 2).
ShatterPoint
Glassbreak Sensor
Models
5600-W, 5605-W, 5620-W, 5625-W
Installation Instructions
Figure 1b. Facing Mounting
Figure 2. Mounting and Cover Screws
Cover Screw
Przeglądanie stron 0
1 2 3 4

Podsumowanie treści

Strona 1 - Glassbreak Sensor

1ShatterPoint Glassbreak SensorMounting DescriptionThe 5600 Glassbreak Sensors are designed to detectbreaking glass caused by forced entry into a prot

Strona 2 - 3/4"

2ShatterPoint Glassbreak SensorFigure 7. Output Circuit (shown powered)Reed Switch ModelsModels 5620 and 5625 require the magnet be mounted onthe movi

Strona 3 - Testing

3ShatterPoint Glassbreak SensorRange Rap Glass Out of Range Out of Within Within RangeTest Range RangeAlarm Rap Glass & No Alarm No Alarm No Alarm

Strona 4 - Ordering Information

Voltage .................. 9 – 16V DCCurrent............ 12mA typ

Komentarze do niniejszej Instrukcji

Brak uwag