NS2503-24P/2C User Manual
107
Follow the rule as below to configure the MAX Age, Hello Time, and Forward Delay Time.
2 x (Forward Delay Time value –1) > = Max Age value >= 2 x (Hello Time value +1).
Each switch in a spanning-tree adopts the Hello Time, Forward Delay time, and Max Age
parameters of the root bridge, regardless of how it is configured.
Root Bridge Information
This page provides a status overview for all STP bridge instances.
The displayed table contains a row for each STP bridge instance, where the column displays the following information:
The STP Bridge Status screen in Figure 4-8-5 appears.
Figure 4-8-5: STP Bridge Status Page Screenshot