IFS NS3552-8P-2S AND NS3550-2T-8S User Manual
145
4.6.10.3 Port Isolate
The diagram shows how the Managed Switch handles isolate and promiscuous ports, and the each PC is not able to access each
other PCs of each isolate port. But they all need to access with the same server/AP/Printer. The screen in Figure 4-6-14 appears.
This section will show you how to configure the port for the server that could be accessed by each isolate port.
Figure 4-6-14: The Port Isolate VLAN Diagram
Setup steps
1. Assign Port Mode
Set Port-1~Port-4 in Isolate port.
Set Port5 and Port-6 are in Promiscuous port. The screen in Figure 4-6-15 appears.