IFS NS3552-8P-2S AND NS3550-2T-8S User Manual
319
PD Class
Display the class of the PD attached to the port, as established by the classification
process. Class 0 is the default for PDs. The PD is powered based on PoE Class level
if system working on Classification mode. A PD shall return Class 0 to 4 in
accordance with the maximum power draw as specified by Table 4-16-1.
Power Used [W]
The Power Used shows how much power the PD currently is using.
Current Used [mA]
The Power Used shows how much current the PD currently is using.
Priority
The Priority shows the port's priority configured by the user.
Port Status
The Port Status shows the port's status.
AF / AT Mode
Display per PoE port operates at 802.3af or 802.3at mode.
(NS3552-8P-2S Supports Only)
Total
Show the total power and current usage of all PDs.
Buttons
Auto-refresh : Check this box to enable an automatic refresh of the page at regular intervals.
: Click to refresh the page immediately.