a 0, the built-in communicator is disabled and the NX-6V2
functions as a local-only control.
Table 4 communicator formats
Data Format
Description
0 Local Communicator is disabled
1 Universal 4+2 Two-digit event code 1800 Hz transmit
2300 Hz handshake double round parity
40 pps [1]
2 3+1 fast (or 4+1) One-digit event code 1900 Hz transmit
1400 Hz handshake double round parity
20 pps
3 Reserved Reserved
4 Pager Two-digit event code DTMF
transmission
5 3/1 or 4/1 slow 1800 Hz transmit 2300 Hz handshake
double round parity 20 pps hex
capability
6 3/1 or 4/1 slow 1800 Hz transmit 1400 Hz handshake
double round parity 20 pps hex
capability
7 3/1 or 4/1 fast 1800 Hz transmit 2300 Hz handshake
double round parity 40 pps hex
capability
8 3/1 or 4/1 fast 1800 Hz transmit 1400 Hz handshake
double round parity 40 pps hex
capability
9 3/1 or 4/1 fast with
parity
1800 Hz transmit 2300 Hz handshake
single round parity 40 pps hex capability
10 3/1 or 4/1 fast with
parity
1800 Hz transmit 1400 Hz handshake
single round parity 40 pps hex capability
11 4+2 express Two-digit event code DTMF
transmission
12 4+2 fast Two-digit event code 1900 Hz transmit
1400 Hz handshake double round parity
20 pps
13 Ademco contact ID DTMF
14 SIA Frequency shift keys
15 Custom format See Loc
16 3/1 or 4/1 slow Same as 5, but sends the alarm event
code rather than the zone number
17 3/1 or 4/1 slow Same as 6, but sends the alarm event
code rather than the zone number
18 3/1 or 4/1 fast Same as 7, but sends the alarm event
code rather than the zone number
19 3/1 or 4/1 fast Same as 8, but sends the alarm event
code rather than the zone number
20 3/1 or 4/1 fast with
parity
Same as 9, but sends the alarm event
code rather than the zone number
21 3/1 or 4/1 fast with
parity
Same as 10, but sends the alarm event
code rather than the zone number
22 SIA SIA with area modifiers
[1] pulses per second
Location 3 - Phone 1 dial attempts/backup control
Location 3 has two segments of numerical data.
Segment 1 - Phone 1 dial attempts
Program the number of dial attempts (1 to 15) the
communicator makes to phone 1 before ending the notification
process. The default is 8, which means that the communicator
makes eight attempts to the first number.
Segment 2 - Phone 1 backup control
Program the b
ackup control for phone 1. The default is 0.
Program a 0 in segment 2 to cause the NX-6V2 to make
the designated number of attempts to phone 2 before
setting the fail to communicate condition to stop reporting.
Program a 1 in segment 2 to cause the NX-6V2 to stop
trying to communicate after the designated number of
attempts have been made to phone 1.
Program a 2 in segment 2 to cause the NX-6V2 to make
the dial attempts in increments of two. The first two
attempts are made to phone 1, the next two attempts to
phone 2. This repeats until the total number of attempts
designated in segment 1 is completed.
Location 4 - Phone 1 events reported
Location 4 has two segments of feature selection data. Use
this location to select those events reported to phone 1.
If you do not want dual or split reporting, use Location 4 to
select all events to phone 1.
If you want dual or split reporting and the split is based on
the event type (alarm, open/close, etc.), use Location 4 to
select only those events that are reported to phone 1.
If you don’t want events reported to phone 1, program 0 in
Location 4 (disabling all options).
Segment 1
1. Alarms and alarm restores.
2. Opening and closings.
3. Zone bypass and bypass restores.
4. Zone trouble and trouble restores.
5. Power fail, low battery, power restore, and low battery
restore.
6. Bell cut, telephone line cut, bell cut restore, telephone line
restore.
7. Test reports.
8. Start and en
d programming, download complete.
4 NX-6V2 Control Panel Installation Instructions