SPECIFICATIONS
ALL MODELS
Range of Coverage...................................................................... 10' (3.1 m)
Resistance: Normal .................................................. <15 ohms (closed)
Alarm ............................................ >1.0 megaohms (open)
Time Open on Alarm ................................................................. 2-6 seconds
Maximum Loop Rating ......................................................... 16V DC, 50 mA
Wire Lead Size ......................................................................... 16-22 gauge
Mounting ........................................................................ Tape pad or screws
Dimensions .......................................................... 3.46" L x 1.1" W x 0.84" H
(8.8 cm x 2.8 cm x 2.1 cm)
BATTERY MODELS (5414, and 5415A)
Battery Type ...................................................................................... Lithium
Battery Life ....................................................................15 years (estimated)
Number of Leads .................................................................... 2 (alarm loop)
POWERED MODELS (5425)
Operational Voltage ....................................................................... 9-16V DC
Current Draw ..................................................................... 15 mA maximum
Number of Leads ......................................................................................... 4
STEP 3 - TESTING
Once mounted, the sensor is ready for the sensitivity adjustment. Models
with the latching LED option should be adjusted before opening the spring
clip.
1. Use a small screwdriver to turn the potentiometer counterclockwise
as far as it will go. Then turn the potentiometer slightly clockwise.
2. Rap the glass firmly about 1' (30.5 cm) in from the farthest corner
(see Figure 4). Use the plastic handle of a medium screwdriver
(about 10" [25.4 cm] long) to do this.
3. If the LED does not light, turn the potentiometer further in the
clockwise direction, and rap the glass again. Continue this procedure
until the LED lights.
On windows greater than 10 sq. ft. (1 sq. m), verify setting by rapping
adjacent corners. This setting should yield the proper protection with a high
degree of false alarm immunity. For multiple sensor applications, coverage
of sensors should overlap.
Latching LED Models
To engage latching LED feature on model 5425, open the spring clip.
Finish the installation by carefully snapping on the cover.
NOTE:
Range is reduced on windows that open if the window is lined
with felt or a gasket for tight sealing. This lining can effectively block
shock transmission to the frame mounted sensor. Sliding glass doors will
likely require two sensors. Test sensor at least annually to ensure proper
operation.
R
0.60"
1.5 cm
3.46"
8.8 cm
R
0.84"
2.1 cm
1.10"
2.8 cm
2.5"
6.5 cm
0.54"
1.4 cm
DIMENSIONS
Sensor
Screwdriver
1'
(30.5 cm)
Model Description Loop Color Listing
Number Configuration
5414-W Lithium battery, tamper, 2-wire NC White UL
5414-M Lithium battery, tamper, 2-wire NC Mahogany brown UL
5415A-W Lithium battery, tamper, 2-wire, alarm loop reed switch, magnet NC White UL
5415A-M Lithium battery, tamper, 2-wire, alarm loop reed switch, magnet NC Mahogany brown UL
5425-W External power, 4-wire, latching LED option NC White
5425-M External power, 4-wire, latching LED option NC Mahogany brown
ORDERING INFORMATION
Figure 4. Rap test
G-3764-0499
1030899 Rev A