Access to the Mirror Inside the
Sensor Module
This access is only required when masking
individual curtains.
Undo the screw (5) and open the sensor
module (6) (see Figure 1).
The two mirrors are accessible now.
Selecting the Coverage Patterns
Mask the appropriate mirror curtains with
the adhesive labels provided and
reassemble the sensor module.
For example, see Figure 4 for mirror
curtain coverage pattern corresponding to
curtain 4 and 8 masked.
Masking Coverage Patterns Field of View
Input power ............................................................... 12 or 24V (7–28V)
Peak to peak ripple ...................................................... 2V max. (at 12V)
Current consumption
Normal operation .................................................... 11 mA (at 12V)
Alarm ............................................................. 13 mA max. (at 12V)
Specified mounting height..................................... 8 – 16 ft (2.4 - 4.8m)
Target speed range ............................................ min. 0.9 – max. 12.0 ft/s
Alarm output....................................................... 50 mA at 28 V Form C
Connection and Programming
Switch 1: Programming the LED
ON LED enabled
OFF LED disabled
Switch 2: Programming the processing
ON Enables Bi-curtain processing designed for harsh environment.
OFF Provides the standard 4D processing.
Switch 3: Programming the detection pattern
ON Provides a 180° field of view for special applications.
OFF Gives the normal 360° field of view.
Note: An arrow in the mounting plate (4) (see Figure 1 and Figure
2) and inside the sensor module shows the always active coverage
pattern. The coverage pattern opposite to the arrow can be disabled
by setting switch 3 in the “ON” position.
Alarm time ............................................................................ min 2.5 sec.
Tamper output .................................................................100 mA at 28 V
Temperature limit ............................... 0°F to +131°F (–18°C to +55°C)
Relative humidity .................................................................... max. 93%
Size ................................. 5.43 in. dia. x 2.68 in. (138mm dia. x 68 mm)
Weight................................................................................... 4.25 ounces
Number of curtains .............................................................................. 18
Max. detection range ................. 60 ft (18m) diameter, 30 ft (9m) radius
Listings .....................................................................................C-UL US
Figure 3
Figure 4
Specifications
123456789
1
ON
10
ñ+
ALARM
NC C NO
TAMPER SPARE
2 3
5
4
3
2
1
6
7
8
9
123 4 5 678 9
30'
1.8ft
shadedareaisshunted
whenswitch3isON
90°
1.8ft
1.8ft
48°
48°
1.8ft
20°
5.4ft
60°
MountingHeight
8—16ft
1&9
2&8
3&7
4&6
5
33
Switch Description On Off
1 LED enable LED on LED off
2 Processing Bi-curtain Standard-4D
3 Detection pattern 180° 360°
Mounting Height Application Note
When increased mounting heights are used outside the specified mounting height range of 8 - 16 ft (2.4 - 4.8m), sensitivity will be reduced.