Interlogix DD669-U Instrukcja Użytkownika Strona 2

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 12
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 1
5
1
1
2
3
4
5
6
7
8
9
9
8
7
6
5
4
3
2
10 m
(32 ft. 10 in.)
8 m
(26 ft. 3 in.)
6 m
(19 ft. 8 in.)
4 m
(13 ft. 2 in.)
2 m
(6 ft. 7 in.)
0 m
2 m
(6 ft. 7 in.)
4 m
(13 ft. 2 in.)
6 m
(19 ft. 8 in.)
8 m
(26 ft. 3 in.)
10 m
(32 ft. 10 in.)
> 3 m
(> 9 ft. 10 in.)
10 m
(32 ft. 10 in.)
10 m
(32 ft. 10 in.)
0 m
1
1
2
3
4
5
6
7
8
9
9
8
7
6
4
3
2
10 m
(32 ft. 10 in.)
8 m
(26 ft. 3 in.)
6 m
(19 ft. 8 in.)
4 m
(13 ft. 2 in.)
2 m
(6 ft. 7 in.)
0 m
2 m
(6 ft. 7 in.)
4 m
(13 ft. 2 in.)
6 m
(19 ft. 8 in.)
8 m
(26 ft. 3 in.)
10 m
(32 ft. 10 in.)
2.5 3 m-
(8 ft. 2 in. - 9 ft. 10 in.)
10 m
(32 ft. 10 in.)
10 m
(32 ft. 10 in.)
0 m
(1) (2)
(3)
(4)
(3)
(4)
6
The detector can be mounted on a ceiling. Use the following
guidelines to determine the best location to install the detector:
1 2
3
4
1
5
6
7
8
9
10
0V +12V
NC
C
NO
SpareD/N
WT
Tamper
Alarm
<R33
DD669-U
Mount the detector so the expected movement of an
intruder is across the detection pattern.
Mount the detector at a stable surface at a height between
2.5 m (8 ft. 2 in.) and 5.0 m (16 ft. 5 in.).
Do not mount the detector within 0.5 m (1 ft. 8 in.) of
metallic objects or within 1.5 m (4 ft. 11 in.) of fluorescent
lights.
Do not place objects in front of the detector that may
prevent a clear line of sight (Figure 1).
Mount detectors at least 6 m (19 ft. 8 in.) apart, and use
the short-range setting to avoid interference.
EN: Installation Sheet
T
he dual technology processing of this detector is very
resistant to false alarm hazards. However, avoid potential
causes of instability, such as:
Description
PIR hazards (F
igure 1):
The DD669-U is a dual motion sensors. It has the patented
Ran
ge Controlled Radar technology.
Direct sunlight on the detector
Heat sources within the detector field of view
Installation guidelines
Strong air draughts onto the detector
Animals in the field of view
Figure 5 legend
Obscuring the detector field of view with large objects,
such as furniture
Item Descrip
tion
(1) Floor pattern at mounting heights between 2.5 and 3.0 m
(8 ft. 2 in. and 9 ft. 10 in.)
(2) Floor pattern at mounting heights above 3.0 m (9 ft. 10 in.)
(3) Shaded area is shunted when DIP switch 4 is in On position
(4) An arrow inside the mounting plate and sensor module
indicates the Always Active direction
Micro
wave hazards:
Mounting surface susceptible to vibrations
Metal surfaces reflecting microwave energy
Water movement through plastic pipes
Moving or vibrating objects like fans, heating or air-
conditioning ducts
W
e recommend that the detector is regularly walk tested and
checked at the control panel.