Interlogix Concord 4 User Manual Instrukcja Użytkownika Strona 64

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 63
62 Concord 4 User Manual
Command Programming sequence
Arm to Level 3 (away) Attaching schedules for arming to Level 3 (away) operation.
Schedule 0: *, 066000, 1 (off) or 2 (on), #
Schedule 1: *, 066001, 1 (off) or 2 (on), #
(continues through schedule 15)
Energy saver Setpoints (enter temperature value in Fahrenheit)
Low: *, 070, nn, #
High: *, 071, nn, #
Factory code *, 010
System number *, 011
Software version *, 013
Attach lights to sensors Attaching lights to sensors.
Light 1: *, 080, nn (sensor number to be attached), #
Light 2: *, 082, nn (sensor number to be attached), #
(continues through Light 9)
Exit programming menus *, 00, #
Przeglądanie stron 63
1 2 ... 59 60 61 62 63 64 65 66 67 68 69 ... 87 88

Komentarze do niniejszej Instrukcji

Brak uwag