2BChapter 3: Camera configuration
26 TruVision IP Camera Configuration Manual
Channel Triggers the recording to start in the camera.
Trigger external alarm outputs when an event occurs.
Note: This option is only supported by cameras that support
alarm output.
10. Click Save to save changes.
Tamper-proof alarms
You can configure the camera to trigger an alarm when the lens is covered and
to take an alarm response action.
To set up tamper-proof alarms:
1. In the Events folder (1), click the Tamper-proof tab (2) to open its window.
2. Check the Enable Tamper-proof box (3).
3. Click Draw Area (4). Click and drag the mouse on the live video image to
draw a tamper-proof area.
4. Click Stop Drawing to finish drawing. Click Clear All to delete all areas
marked and restart drawing.
5. Move the Sensitivity slider (5) to set the sensitivity of the detection.
All areas will have the same sensitivity level.
6. Click Edit to edit the arming schedule for tamper-proof alarms. The arming
schedule configuration is the same as that for motion detection. See “To set
up motion detection” for more information.
7. Check the checkbox to select the linkage method taken for the tamper-proof.