2BChapter 3: Camera configuration
TruVision IP Camera Configuration Manual 27
8. Click Save to save changes.
Exception alarms
You can set up the camera to notify you when irregular events occur and how
you should be notified. These exception alarms include:
• HDD Full: All recording space of NAS is full.
• HDD Error: Errors occurred while files were being written to the storage, no
storage or storage had failed to initialize.
• Network Disconnected: Disconnected network cable.
• IP Address Conflicted: Conflict in IP address setting.
• Illegal Login: Wrong user ID or password used to login to the cameras.
Figure 10: Exception menu
To define exception alarms:
1. In the Events folder, click the Exception tab to open its window.
2. Under Exception Type, select an exception type from the drop-down list.
3. Check the checkbox to select the linkage method.
4. Click Save to save changes.
Alarm inputs and outputs
To define the external alarm input:
1. In the Events folder, click the Alarm Input tab to open its window.
2. Choose the Alarm Input No. and the Alarm Type. The alarm type can be NO
(Normally Open) and NC (Normally Closed). Enter a name for the alarm input.