2BChapter 3: Camera configuration
TruVision IP Camera Configuration Manual 31
Pre-record time
The pre- record time is set to start recording before the scheduled time or the
event. For example, if an alarm triggers recording at 10:00, and the pre-record
time is set as 5 seconds, the camera starts to record at 9:59:55. The pre-record
time can be configured as No Pre-record, 5 s, 10 s, 15 s, 20 s, 25 s, 30 s, or not
limited.
Post- record time
The post-record time is set to stop recording after the scheduled time or the
event. For example, if an alarm triggered recording ends at 11:00, and the post-
record time is set as 5 seconds, the camera records until 11:00:05. The post-
record time can be configured as 5 s, 10 s, 30 s, 1 min, 2 min, 5 min, or 10 min.
To set up a recording schedule:
1. In the Storage folder, click the Record Schedule tab to open its window.
2. Click the Enable Record Schedule box to enable recording.
Note: To disable recording, deselect the option.
3. Click Edit to edit the recording schedule. The following window appears:
4. Select whether the recording will be for the whole week (All Day recording) or
for specific days of the week.
If you have selected “All day”, select one of the record types to record from
the drop-down list box:
• Normal: This is continuous recording.
• Motion detection: The video is recorded when the motion is detected.
• Alarm: The video is recorded when the alarm is triggered via the external
alarm input.
• Motion | Alarm: The video is recorded when the external alarm is
triggered or the motion is detected.